At SR AIR SYSTEMS, we are committed to delivering reliable cleanroom and laboratory equipment that meets defined quality norms and industry guidelines. Our focus on quality, dependable solutions, and customer satisfaction helps us serve diverse industrial requirements.

Laminar Air Flow

Laminar Air Flow

Laminar Air Flow Hood Manufacturer & Supplier in India

SR Air System is a Laminar Air Flow Hood manufacturer and supplier in Ahmedabad, Gujarat, India, offering airflow equipment for laboratories, pharmaceutical facilities and controlled work environments. Our range includes Laminar Air Flow Cabinet designs and application-specific units to support clean working areas and sensitive material handling.

We offer solutions for pharmaceutical research, laboratory testing, healthcare and industrial applications. Available configurations include stainless steel and powder-coated construction options, with filtration, airflow direction and dimensions selected according to the model and application requirements.

Why Choose Our Laminar Air Flow Cabinets?

Our laminar airflow equipment is designed with a focus on reliable operation, cleanable construction and practical working-area requirements.

  • HEPA Filtration: Filtered airflow configurations designed to help reduce airborne particles in the protected working area.
  • Material Options: Stainless steel and powder-coated construction options depending on the selected model.
  • Airflow Configurations: Horizontal and vertical airflow arrangements for different laboratory and cleanroom applications.
  • Practical Design: Accessible workspaces, easy-to-clean surfaces and maintenance-friendly construction.
  • Application-Based Solutions: Equipment selection according to work area, filtration requirements and operating conditions.

LAF Solutions by SR Air System

SR Air System offers a range of laminar airflow equipment, including Horizontal Laminar Air Flow Unit, Vertical Laminar Air Flow Chamber and other configurations for laboratory and industrial applications.

 

Our Laminar Air Flow for Laboratory solutions include portable, mobile, stand-mounted and ceiling-suspended models. Explore the nine products below to compare available designs and select a suitable unit for your application.

Laminar Air Flow Unit for Cleanroom and Laboratory Applications

Horizontal Laminar Flow Cabinet

Ideal for clinical research and pharmaceutical labs where the sample requires the cleanest possible air before it reaches the operator.
Vertical Laminar Air Flow Cabinet for Cleanroom and Laboratory Applications

Vertical Laminar Air Flow

Perfect for micro-electronics assembly and pharmacy applications. These units occupy less floor space and provide a protective curtain of air.

Stand Mounted Laminar Air Flow​

Designed for flexibility, our mobile units feature medical-grade PU castors with brakes, allowing for “clean zone” movement across different lab sections.

Portable Laminar Flow Cabinet for Laboratory and Cleanroom Applications

Portable Laminar Flow Cabinet

A versatile, freestanding cabinet that offers flexibility and easy integration into any lab or cleanroom layout.

Ceiling Suspended Laminar Air Flow Unit for Cleanroom Applications

Ceiling Suspended Laminar Air Flow Unit

An innovative solution for maintaining sterility in large areas, such as operation theaters, without occupying floor space.

Reverse Laminar Air Flow Unit for Pharmaceutical and Cleanroom Applications

Reverse Laminar Air Flow

Also known as Sampling/Dispensing Booths, these protect the operator from hazardous powder or chemical fumes during material transfer.

OT Room Laminar Air Flow Unit for Operation Theatre

OT Room Laminar Air Flow

Specialized Plenum systems designed to create sterile surgical zones in hospitals.

MS Vertical Laminar Air Flow Cabinet for Laboratory and Cleanroom

MS Vertical Laminar Air Flow

An economical powder-coated Mild Steel option for budget-conscious laboratory setups.

Mobile Laminar Air Flow Unit for Cleanroom and Laboratory Applications

Mobile Laminar Air Flow

Equipped with high-grade castor wheels for safely transporting sterile products between clean zones without risking contamination.

Laminar Air Flow Technical Specification

Choosing the right airflow direction is critical for your application. We manufacture both Horizontal and Vertical configurations to suit your cleanroom needs.

FeatureHorizontal LAFVertical LAF
Material (MOC)SS 304 / SS 316 / MS Powder CoatedSS 304 / SS 316 / MS Powder Coated
FiltrationHEPA H14 (Efficiency 99.999%)HEPA H14 (Efficiency 99.999%)
Pre-Filter10 Micron (Washable Nylon)10 Micron (Washable Nylon)
Air Velocity0.45 m/s ± 20%0.45 m/s ± 20%
CleanlinessISO Class 5 (Class 100)ISO Class 5 (Class 100)
IlluminationLED Light & UV Germicidal LampLED Light & UV Germicidal Lamp
Vibration LevelMinimum (Low Noise Blower)Minimum (Low Noise Blower)
Power Supply230V AC, 1 Phase, 50Hz230V AC, 1 Phase, 50Hz
Best ForLarge Samples, Non-Hazardous MaterialsSpace Saving, Pharmacy Compounding
Filter PositionBack Wall (Rear Mounted)Top Mounted
Contamination RiskLower(Airflow clears samples first)Higher (if hands are above samples)
Air Flow DirectionOutward towards the operatorDownwards towards the work surface

Standard Components:

  • Pre-Filters: 10-micron efficiency (Washable Synthetic Fiber).
  • HEPA Filters: Mini-pleat HEPA filters with aluminum separators.
  • Illumination: High-intensity LED lighting (>800 Lux).
  • Monitoring: Analog or Digital Magnahelic Pressure Gauges.

FAQs

A laminar air flow system ensures unidirectional airflow through HEPA filters, providing a sterile environment for laboratories and industrial applications.
Horizontal systems are ideal for small-scale sample handling, while vertical systems are preferred for sensitive sterile work requiring downward airflow. We manufactures both types that fulfill your needs.
Yes, all our units meet ISO 14644-1 cleanroom standards for controlled environments.
Absolutely! We provide custom sizes, materials, and features to meet your lab requirements.
Pharmaceutical labs, hospitals, research institutes, cleanrooms, and food processing units rely on these systems for particle-free environments.
Typically every 2–3 years depending on usage and environment. We recommend monitoring the differential pressure gauge; once it exceeds the initial pressure by 2x, it’s time for a change.
SS 304 is standard for most labs, while SS 316 is recommended for environments using corrosive chemicals or high-salinity cleaning agents.

Ready to Build Your Ideal Cleanroom?

SR Air System is a trusted name in the world of cleanroom and contamination control solutions, specializing in all types of Laminar Air Flow Cabinets, Air Showers units, Dynamic & Static Pass Boxes, Clean Room Pass Boxes, Dispensing Booths, Biosafety Cabinets and a complete range of Laboratory Equipments.

Our Visitor

0 0 0 7 2 1
Users Today : 2
Users This Month : 625
Total Users : 721

Our Visitor

0 0 0 7 2 1
Users Today : 2
Users This Month : 625
Total Users : 721