Stand Mounted Laminar Air Flow for Laboratory Workstations
Stand Mounted Laminar Air Flow is a stainless steel clean bench offered by SR Air System in Ahmedabad, Gujarat, India. The listed model combines a stand-supported working area, vertical airflow configuration and HEPA filtration for suitable pharmaceutical and laboratory tasks.
Featuring a 4 ft working width and a listed 2 ft work-zone height, the cabinet provides a raised working surface for preparing and handling approved non-hazardous materials. Its SS 304 construction, polished finish and centrifugal blower are specified for the supplied model.
Buyers comparing laboratory workstations can explore our Laminar Air Flow equipment range to review different mounting and airflow configurations.

Stand Mounted Laminar Flow Cabinet | SR Air System

Stand Mounted Laminar Air Flow Overview & Working Principle
A stand-mounted clean bench combines a supported working chamber with an airflow and filtration arrangement. Its support structure positions the working surface at a practical operating height without requiring a separate laboratory table.
According to the supplied specification, this model uses a vertical airflow arrangement. Air is moved by a centrifugal blower through the specified filtration system to help reduce airborne particles in the working zone. The actual airflow direction and installed filter position must be confirmed.
This Stand Mounted Laminar Flow Cabinet is intended for suitable product-protection applications rather than hazardous-material containment. Other laboratory airflow configurations are available through our laminar airflow cabinet collection .
- Integrated stand and supported work surface
- SS 304 stainless steel construction
- Listed vertical airflow configuration
- HEPA H14 filtration, subject to test verification
- Centrifugal blower arrangement
- Polished finish and fluorescent illumination
Key Features of Stand Mounted Laminar Air Flow
This configuration emphasizes a self-supported working area, stainless steel construction and filtered airflow for suitable laboratory operations.
Stand-Mounted Structure
The working chamber is supported by an integrated stand, providing a dedicated workstation for laboratory and pharmaceutical use.
Vertical Airflow Design
A vertical airflow configuration is specified. The actual air path and performance should be verified for the supplied unit.
HEPA H14 Filter
An H14 HEPA filter is listed for particle removal. Its certification and installed performance must be checked.
SS 304 Construction
Stainless steel surfaces offer corrosion resistance and support routine cleaning with compatible cleaning agents.
Centrifugal Blower
The specified centrifugal blower drives airflow through the cabinet. Blower capacity and noise performance require technical confirmation.
Fluorescent Lighting
Fluorescent illumination is listed for visibility within the working area. Final lighting and control arrangements depend on the supplied configuration.
Stand Mounted Laminar Air Flow Specifications
| Parameter | Details |
|---|---|
| Product Name | Stand Mounted Laminar Air Flow |
| Manufacturer | SR Air System |
| Product Type | Stand Mounted Laminar Flow Cabinet |
| Airflow Type | Vertical, as Listed |
| Construction Material | SS 304 Stainless Steel |
| Listed Material Brand | Jindal; Supplier Documentation to Confirm |
| Surface Finish | Polished |
| Working Width | 4 ft, as Listed |
| Work Zone Height | 2 ft, as Listed |
| Filter Type | HEPA H14; Performance to Verify |
| Blower Type | Centrifugal |
| Listed Power Supply | 230 V AC, Single Phase |
| Lighting | Fluorescent |
| Listed Noise Level | 65 dB; Test Verification Required |
| Finish Color | Silver |
| Cleanliness Target | ISO Class 5 Listed; Testing Required |
| Usage | Pharmaceutical & Laboratory Applications |
| Installation | Stand Supported; Site Requirements to Confirm |
| Country of Origin | India |
Specifications are based on the submitted listing. Confirm actual airflow direction, overall dimensions, electrical rating, filter certification, noise level and ISO cleanliness performance before ordering.
Laboratory & Pharmaceutical Applications
Stand-mounted clean benches are considered where a dedicated working surface and filtered-air environment are required for suitable non-hazardous tasks.
Pharmaceutical Laboratories
Handling of approved non-hazardous materials during laboratory preparation activities.
Research Workstations
Preparation and observation of suitable samples in a particle-controlled working area.
Component Inspection
Examination of clean components where airborne particles could interfere with product quality.
Laboratory Support Areas
Dedicated bench space for appropriate handling and preparation of approved clean materials.
The right clean bench depends on work-zone dimensions, construction material, airflow pattern and laboratory procedures. Compare other Laminar Air Flow models before making a final selection.
Stand Mounted Laminar Air Flow Manufacturer in Ahmedabad
SR Air System manufactures and supplies cleanroom and laboratory equipment from Ahmedabad, Gujarat, India. Our laminar airflow range includes stand-mounted, horizontal, vertical and other workstation configurations.
As a Stand Mounted Laminar Air Flow Supplier, SR Air System works with buyers who need to evaluate workstation width, stainless steel construction, filtration requirements and installation conditions.
A suitable cabinet must be selected according to the actual working process, required product protection and available laboratory space. Learn more about the company through the SR Air System company profile .
What to Confirm Before Ordering
- Required working width and work-zone height
- Stand height, support arrangement and installation space
- Actual vertical airflow direction and filter position
- HEPA H14 certification and test documentation
- Blower output, noise level and electrical requirements
- Surface finish, illumination and optional accessories
For Stand Mounted Laminar Air Flow Price enquiries, share your required working dimensions, material of construction, filtration specifications and installation requirements. Our team can discuss a suitable configuration and quotation.
Important: A conventional laminar flow clean bench is intended to protect suitable products and samples from particles. It is not a substitute for operator-containment equipment when handling hazardous biological or chemical materials.
Stand Mounted Laminar Air Flow FAQs
What is a stand mounted laminar air flow cabinet?
It is a laminar flow clean bench fitted to a supporting stand. The integrated structure provides a dedicated work surface for suitable non-hazardous laboratory applications.
Is this a vertical or horizontal airflow model?
The supplied technical specification identifies a vertical configuration. The actual airflow direction and filter location should be confirmed for the final supplied cabinet.
Which material is used for construction?
The submitted listing identifies SS 304 stainless steel with a polished finish. Material sourcing and the final construction specification should be confirmed before ordering.
Does the unit include HEPA H14 filtration?
HEPA H14 is included in the supplied product specification. Buyers should confirm filter documentation, installation details and actual performance test results.
Is the workstation certified for ISO Class 5?
ISO Class 5 is stated in the original listing. Actual airborne-particle cleanliness must be demonstrated through appropriate testing under defined conditions.
Does stand mounted mean the unit is mobile?
Not necessarily. Stand mounted describes the supporting structure. Mobility depends on whether the ordered unit includes suitable castors or another approved moving arrangement.
Compare Stand-Mounted and Other Clean Bench Models
A stand-mounted workstation is selected partly for its integrated support arrangement and working-area layout. Other laminar airflow products may differ in portability, construction material and airflow direction.
For additional laboratory workstations and airflow configurations, browse the complete Laminar Air Flow category and discuss your requirements with SR Air System.