At SR AIR SYSTEMS, we are committed to delivering reliable cleanroom and laboratory equipment that meets defined quality norms and industry guidelines. Our focus on quality, dependable solutions, and customer satisfaction helps us serve diverse industrial requirements.

Industrial Air Shower Unit

Industrial Cleanroom Entry Equipment

Industrial Air Shower Unit for Controlled Personnel Entry

Industrial Air Shower Unit is an automatic cleanroom entry chamber manufactured and supplied by SR Air System in Ahmedabad, Gujarat, India. It uses directed, high-velocity air jets to help dislodge loose dust, lint and surface particles from suitable personnel clothing before entering designated controlled areas.

The listed model features SS 304 stainless steel construction, floor-mounted installation, recirculating airflow, an interlocking access arrangement and a three-phase electrical system. HEPA filtration and a pre-filter are also specified.

Industrial air shower equipment supports facility entry procedures, but does not replace protective clothing, housekeeping or approved contamination-control practices. Explore our Air Shower Unit collection for other personnel entry configurations.

Industrial Air Shower Unit with stainless steel entry door, viewing window, pressure gauge and control panel by SR Air System

Industrial Air Shower Unit | SR Air System

SS 304 Construction
Automatic Operation
HEPA Filtration Listed
Interlocking Entry
SR Air industrial air shower enclosure with windowed entry door and visible air jet nozzles
Product Overview

Industrial Cleanroom Air Shower Design & Working Principle

An Industrial Cleanroom Air Shower provides a dedicated transition chamber at the entrance to a controlled working area. It is intended to help manage loose surface particles carried on appropriate work clothing.

During a typical cycle, the operator enters the chamber and closes the entry door. An automatic control system activates the blower and directs filtered air through strategically arranged nozzles.

High-velocity airflow helps dislodge particles from garment surfaces. The system then recirculates air through its specified filtration arrangement. The submitted specification lists an H14 HEPA filter and a 10-micron pre-filter.

The interlocking system coordinates door access according to the configured operating cycle. The exact timer, door sequence and emergency-release requirements should be verified during commissioning.

The model is listed for industrial use and should be evaluated against the facility's room conditions, personnel traffic and available installation space.

  • Floor-mounted cleanroom entry chamber
  • SS 304 stainless steel cabinet and nozzles listed
  • Automatic blower-driven air shower operation
  • H14 HEPA and pre-filter combination listed
  • Interlocking access door arrangement
  • Recirculating airflow and adjustable cycle options to verify
Product Features

Industrial Air Shower Unit Features & Construction

Key selection factors include chamber construction, air delivery, filtration, automatic controls, interlocking and installation requirements.

High-Velocity Air Nozzles

SS 304 air nozzles are listed for directing high-speed airflow at personnel garments. Final jet velocity must be verified at the specified measurement point.

HEPA Filtration System

The specification lists H14 HEPA filtration along with a pre-filter. Filter grade, integrity testing and performance documentation should be confirmed.

SS 304 Cabinet

Stainless steel 304 is specified for the enclosure and nozzle construction. Confirm sheet thickness, surface finish and cleaning-agent compatibility.

Automatic Door Interlocking

An interlocking access arrangement is listed to coordinate entry and exit door use. The fail-safe operation must be verified.

Automatic Cycle Controls

The model describes automatic operation with configurable air shower timing. Confirm the available settings and exact programmed cycle.

Industrial Floor Installation

Floor-mounted construction supports installation planning at designated cleanroom entrances. Site clearance and service access require confirmation.

Technical Specifications

Industrial Air Shower Unit Technical Specifications

Parameter Listed Details
Product Name Industrial Air Shower Unit
Brand SR AIR / SR Air System
Model Reference SRAS-ASU-2023-2024
Equipment Type Automatic Industrial Cleanroom Air Shower
Installation Floor Mounted
Cabinet Material SS 304 Stainless Steel
Nozzle Material SS 304
Wall Thickness 1 mm Listed; Final Drawing to Confirm
Chamber Configuration Rectangular
Listed Cabinet Size 900 × 900 × 1830 mm
Additional Working Size 900 × 900 × 1850 mm; Verify Dimensions
Listed Height 6.5 ft; Verify Final Height
Personnel Capacity 1 or 1–2 Persons Listed; Confirm Rating
Operating Mode Automatic
Door Operation Interlocking System
Airflow Arrangement Recirculation
Jet Velocity 25 ± 5 m/s Listed; Verify Test
Additional Velocity Value 90 ± 20 FPM Listed; Measurement Point to Confirm
Filtration Grade H14 HEPA Listed
Pre-Filter 10-Micron Pre-Filter Listed
Filter Efficiency Verify Certified Test Data
Blower Double-Shaft Blower Listed
Motor Power 1 HP Listed; Confirm Electrical Load
Electrical Supply 415 V AC, Three Phase Listed
Frequency 50 Hz
Air Shower Cycle 10 / 12 Seconds Listed; Confirm Setting
Timer Range 0–120 Seconds Listed; Confirm Controller
Noise Level 65 dB Listed; Verify Test Conditions
Weight 800 kg Listed; Verify Actual Unit
Cleanroom Application ISO 8 Listed; Site Suitability to Be Assessed
Country of Origin India

These are supplied listing values, not independently verified test results. Confirm capacity, dimensions, equipment weight, timer settings, air jet velocity, filter integrity and electrical rating before ordering.

Industrial Applications

Industrial Cleanroom Air Shower Applications

Air shower systems may be considered for industrial operations that use controlled personnel entry points and documented contamination-control procedures.

Electronics Manufacturing

Personnel entry into designated electronics production and assembly areas.

Precision Manufacturing

Entry transition for workers in production zones with particulate control requirements.

Controlled Packaging Areas

Support for personnel entry into selected packaging and product-handling environments.

Laboratory Support

Integration into laboratory entry workflows where approved personnel air-shower procedures are required.

The suitability of an Industrial Air Shower depends on the room classification, equipment capacity, nozzle arrangement and personnel procedures.

Review the complete Air Shower Unit range for other entry chamber and personnel-capacity configurations.

Manufacturer & Supplier

Industrial Air Shower Unit Manufacturer in Ahmedabad

SR Air System is an Industrial Air Shower Unit Manufacturer based in Ahmedabad, Gujarat, India. The company manufactures and supplies cleanroom entry equipment for industrial, laboratory and pharmaceutical applications.

As an Industrial Air Shower Unit Supplier, SR Air System can discuss stainless steel construction, air jet arrangements, HEPA filtration, electrical controls and installation requirements with buyers.

An Industrial Air Shower Manufacturer should be able to provide model-specific details on chamber dimensions, operating sequence and required filter maintenance.

Buyers seeking an Industrial Cleanroom Air Shower Manufacturer should compare equipment specifications with their facility's intended operating conditions.

Learn more about SR Air System through the company profile .

What to Confirm Before Ordering

  • Approved personnel capacity and internal chamber size
  • SS 304 construction, wall thickness and finish
  • Nozzle arrangement, jet velocity and test conditions
  • HEPA filter grade, test documentation and pre-filter details
  • Door interlocking, timer settings and emergency operation
  • 415 V three-phase supply, motor rating and installation clearances

For Industrial Air Shower Unit Price enquiries, share your required personnel capacity, chamber dimensions, cleanroom entry requirements, filtration specifications and electrical supply.

These details help SR Air System review the equipment configuration and provide a quotation.

Technical Note: Listed H14 filtration, ISO 8 application and airflow values do not establish completed equipment qualification. Final suitability should be assessed through the required project documentation and testing.

Contact Our Team →
Frequently Asked Questions

Industrial Air Shower Unit FAQs

What is an Industrial Air Shower Unit?

It is a controlled personnel-entry chamber that directs high-velocity air jets toward suitable work garments to help reduce loose surface particles before entry into a designated area.

How does an industrial air shower operate?

Personnel enter the enclosure and close the access door. An automatic blower operates for a configured cycle, directing filtered airflow through nozzles. The exit sequence depends on the installed controller.

Does the model include HEPA filtration?

The supplied model description lists an H14 HEPA filter and a 10-micron pre-filter. Filter certification, installed configuration and performance testing should be confirmed.

What is the air shower jet velocity?

One listed specification gives 25 ± 5 m/s. A separate value of 90 ± 20 FPM is also supplied. These values must not be treated as equivalent, and their measurement points require confirmation.

How many people can use the unit at once?

The source contains conflicting descriptions of one person and one to two persons. The approved operating capacity must be confirmed against the chamber dimensions and manufacturer specifications.

Is the air shower automatically operated?

Automatic operation and door interlocking are listed. The actual shower time, controller settings, door logic and emergency release must be checked during commissioning.

What electrical supply is required?

The main specification lists 415 V AC, three-phase, 50 Hz. Final electrical requirements must be verified using the equipment nameplate and installation drawing.

Is the Industrial Air Shower suitable for ISO 8 cleanrooms?

ISO 8 is mentioned as an application in the product listing. Suitability depends on the facility's contamination-control requirements, installation and applicable qualification tests.

Related Air Shower Equipment

Compare Industrial Air Shower Unit with Other Configurations

Industrial and pharmaceutical air showers differ in their intended facility applications, construction requirements and personnel entry arrangements.

For other cleanroom entry systems, browse the complete Air Shower Unit product category from SR Air System.

Ready to Build Your Ideal Cleanroom?

SR Air System is a trusted name in the world of cleanroom and contamination control solutions, specializing in all types of Laminar Air Flow Cabinets, Air Showers units, Dynamic & Static Pass Boxes, Clean Room Pass Boxes, Dispensing Booths, Biosafety Cabinets and a complete range of Laboratory Equipments.

Our Visitor

0 0 0 1 6 8
Users Today : 19
Users This Month : 72
Total Users : 168

Our Visitor

0 0 0 1 6 8
Users Today : 19
Users This Month : 72
Total Users : 168