Pass Box MFG

LAMINAR AIR FLOW SYSTEM

Best Laminar Air Flow Systems Manufacturer in Ahmedabad, India

SR Air System is a leading Laminar Air Flow Systems manufacturer and supplier based in Ahmedabad, Gujarat, India. We specialize in designing and producing a comprehensive range of HEPA-filtered LAF cabinets, workstations, benches  and units that provide ISO-compliant, particle-free work zones.

Our high-quality ISO certified Laminar Air Flow units are essential for ensuring clean and controlled environment for handling sensitive materials in Pharmaceutical Research, Laboratory Testing, IVF Centers, and Operation Theatres. We offer customized units built from corrosion-resistant SS 304 or SS 316 stainless steel.

Why Choose Our Laminar Air Flow Cabinets?

Our systems are engineered for durability and compliance with WHO-GMP and ISO 14644-1 standards.

  • Superior Filtration: Equipped with H14 HEPA filters (99.999% efficiency at 0.3 microns).
  • Material Excellence: Available in high-grade SS 304, SS 316, or GPSP powder-coated finishes.
  • Ergonomic Design: Low-noise blowers (<65 dB) and anti-vibration mounting for long laboratory hours.
  • Safety Integrated: Built-in UV-C germicidal lamps and interlocking systems for operator safety.

Our Range of LAF Solutions

As a premier laminar air flow manufacturer, we specialize in a variety of models to suit Pharmaceutical & cleanroom specific needs:

Horizontal Laminar Flow Cabinet

Ideal for clinical research and pharmaceutical labs where the sample requires the cleanest possible air before it reaches the operator.

Vertical Laminar Air Flow

Perfect for micro-electronics assembly and pharmacy applications. These units occupy less floor space and provide a protective curtain of air.

Stand Mounted Laminar Air Flow​

Designed for flexibility, our mobile units feature medical-grade PU castors with brakes, allowing for “clean zone” movement across different lab sections.

Portable Laminar Flow Cabinet

A versatile, freestanding cabinet that offers flexibility and easy integration into any lab or cleanroom layout.

Ceiling Suspended Laminar Air Flow Unit

An innovative solution for maintaining sterility in large areas, such as operation theaters, without occupying floor space.

Reverse Laminar Air Flow

Also known as Sampling/Dispensing Booths, these protect the operator from hazardous powder or chemical fumes during material transfer.

OT Room Laminar Air Flow

Specialized Plenum systems designed to create sterile surgical zones in hospitals.

MS Vertical Laminar Air Flow

An economical powder-coated Mild Steel option for budget-conscious laboratory setups.

Mobile Laminar Air Flow

Equipped with high-grade castor wheels for safely transporting sterile products between clean zones without risking contamination.

Laminar Air Flow Technical Specification

Choosing the right airflow direction is critical for your application. We manufacture both Horizontal and Vertical configurations to suit your cleanroom needs.

Feature Horizontal LAF Vertical LAF
Material (MOC) SS 304 / SS 316 / MS Powder Coated SS 304 / SS 316 / MS Powder Coated
Filtration HEPA H14 (Efficiency 99.999%) HEPA H14 (Efficiency 99.999%)
Pre-Filter 10 Micron (Washable Nylon) 10 Micron (Washable Nylon)
Air Velocity 0.45 m/s ± 20% 0.45 m/s ± 20%
Cleanliness ISO Class 5 (Class 100) ISO Class 5 (Class 100)
Illumination LED Light & UV Germicidal Lamp LED Light & UV Germicidal Lamp
Vibration Level Minimum (Low Noise Blower) Minimum (Low Noise Blower)
Power Supply 230V AC, 1 Phase, 50Hz 230V AC, 1 Phase, 50Hz
Best For Large Samples, Non-Hazardous Materials Space Saving, Pharmacy Compounding
Filter Position Back Wall (Rear Mounted) Top Mounted
Contamination Risk Lower(Airflow clears samples first) Higher (if hands are above samples)
Air Flow Direction Outward towards the operator Downwards towards the work surface

Standard Components:

  • Pre-Filters: 10-micron efficiency (Washable Synthetic Fiber).

  • HEPA Filters: Mini-pleat HEPA filters with aluminum separators.

  • Illumination: High-intensity LED lighting (>800 Lux).

  • Monitoring: Analog or Digital Magnahelic Pressure Gauges.

FAQs

What is a Laminar Air Flow system?

A laminar air flow system ensures unidirectional airflow through HEPA filters, providing a sterile environment for laboratories and industrial applications.

Horizontal vs. Vertical Laminar Air Flow – which is better?

Horizontal systems are ideal for small-scale sample handling, while vertical systems are preferred for sensitive sterile work requiring downward airflow. We manufactures both types that fulfill your needs.

Are your Laminar Air Flow systems ISO compliant?

Yes, all our units meet ISO 14644-1 cleanroom standards for controlled environments.

Can I get a customized Laminar Air Flow workstation?

Absolutely! We provide custom sizes, materials, and features to meet your lab requirements.

What industries use Laminar Air Flow systems?

Pharmaceutical labs, hospitals, research institutes, cleanrooms, and food processing units rely on these systems for particle-free environments.

How often should HEPA filters be replaced?
Typically every 2–3 years depending on usage and environment. We recommend monitoring the differential pressure gauge; once it exceeds the initial pressure by 2x, it’s time for a change.
What is the difference between SS 304 and SS 316 for LAF?
SS 304 is standard for most labs, while SS 316 is recommended for environments using corrosive chemicals or high-salinity cleaning agents.

Laminar Flow Cabinet Price & Specifications

As a direct Laminar Air Flow manufacturer in Ahmedabad, Gujarat, we offer highly competitive pricing on all our LAF cabinets and customized units. We supply both SS 304 and SS 316 construction to meet diverse industry compliance requirements.

To get the most accurate price, we require your specifications. Contact us today for a free consultation and manufacturer-direct quote.

Stainless Steel Static Hatch Box

Submit requirements for cleanroom equipment.